CAOS Language Guide
Call Button Commands
|
Macro |
Description |
|
Call Buttons should be created immediately after the lift for which they operate - in a top to bottom order. The following commands allow the call buttons to set up the floor levels at which the lifts stop. |
|
|
CBRG |
Call Button register. Notifies the last created lift of this call button's position. This sets the floor level of the lift to be the room surface at this position. Command only |
|
CBRX x y |
Call Button register extended. Notifies the last created lift of this call button and the specified position. This sets the floor level of the lift to be the room surface at the specified position. Command only |